Vista-20P
Control Panel
The high capacity,
feature-rich VISTA-20P lets you deliver more value to your customers on each and
every sale with up to 48 zones of protection and dual partitions. The panel's
installation advantages, innovative end-user benefits and robust system capacity
make the value-priced VISTA-20P
an ideal choice for higher end installations.
Feature:
- Eight on-board hardwire zones standard (15 when Zone Doubling feature is
used)
- Expandable to 48 total zones when used with hardwired and/or wireless
expansion modules
- Wireless keys can be programmed without using zones
- 16 output devices, Relays (Model 4204 Relay Modules, or 4229 Expansion
Module), and/or X-10®devices (when used with a 4300 Transformer)
- Two low current on-board trigger outputs
- 100 Event Log viewable at system keypads with time/date stamp
- 48 system user codes assignable to either partition
- Two independent partitions plus a common partition. Global Arming from any
system keypad. Gotofunction to view or operate one partition from the other.
Separate partition account numbers
- Four installer configurable zone types allows the installer to create
custom zone types by assigning all zone attributes
- Multiple actions on output devices depending on system "state". Turns
lights off when system arms. Turns the same light on when system disarms.
Flashes same lights when system is in alarm
- Built-in phone line cut monitor with programmable delay and annunciation
options. Display on system keypads. Trigger local sounders. Trigger system
bell
- Supports four-wire, and up to 16 two-wire smokes. Works with Sentrol
CleanMe™maintenance signal.
¡@
Specification:
- ELECTRICAL: -
- Aux. power 12VDC, 600mA maximum
- Seven hour standby at 400mA aux. load with four amp hour battery
- 16.5VAC/25VA transformer
- Alarm output 12VDC, 2.0 amps maximum
- For UL installations, combined aux. and alarm output cannot exceed 700mA
- OUTPUT CONTROL: -
- Supports up to four relay boards (up to 16 relays)
- Optional X-10 transformer/interface (part no. 4300) may be used to control
up to 16 X-10 receiving devices
- ZONES: -
- Eight hardwired zones (15 with zone doubling)
- Selectable response 10msec, 350msec, 750msec
- Assignable to any partition
- 20 selectable zone types plus four configurable zone types
- Programmable swinger suppression
- EXPANSION DEVICES: -
- 4219 - Eight hardwired zones - 16mA
- 4204 - Up to four relays - 15mA standby (each active relay draws an
additional 40mA)
- 4229 - Eight hardwired zones and two relays - 36mA (each active relay
draws an additional 40mA)
- ACCESSORIES: -
- 4286 VIP Voice Module - 220mA
- 5881ENL RF Receiver supports up to eight zones - 60mA, 5881ENM supports up
to 16 zones - 50mA,
- 5881ENH up to 40 zones - 50mA
- 5883 Transceiver supports up to 40 zones - 80mA
- Supports Eagle 1225 and 1221 boards
- KEYPADS: -
- 6160 / 6139 Custom English (required for programming) - 150mA/40mA (6160)
130mA/40mA (6139)
- 6150 / 6128 Fixed English LCD - 70mA/40mA (6150), 40mA/20mA (6128)
- 6150RF Fixed English LCD with built-in receiver 105mA/80mA
- AGENCY LISTINGS: -
- UL Residential Fire, Burglary and CSFM
- Smoke Detectors
- Supports up to 16 two-wire smoke detectors
- Supports four-wire smoke detectors
- COMMUNICATIONS: -
- Touchtone or pulse
- Formats supported: ADEMCO Contact ID, ADEMCO 4 + 2 Express, ADEMCO low
speed, Sescoa/Radionics, 3 + 1, 4 + 1 and 4 + 2 reporting
- Reporting capabilities: Split, Dual, Split/Dual - True dial tone detection
- Low battery reports 11.2 - 11.6VDC
- AC loss and restoral reporting supported