Features
¡@ |
| ¡@ | |
|
General Specifications
|
|
|
ELECTRICAL |
|
| Primary Operating Voltage: | 120 VAC, 60 Hz |
| Transformer: | UL listed, Class II, plug-in, 16 VAC, 1.25 A (supplied) |
| Back-Up Battery: | 1.2 Amp-hour, 12 VDC |
|
RADIO RECEIVER |
|
| Type: | Superheterodyne |
| Operating Frequency | 315 MHz ¡Ó 100 Kc |
| Sensitivity: | -100 dB minimum |
| Antenna Type: | Counterpoised bipolar design |
| Compatible RF Formats: | Linear DX, DXS |
|
CONTROL PANEL |
|
| Radio Zones: | 12 supervised |
| PAC Codes: | Eight total, including Duress, Installer, five User and Page Alert |
| Operating Modes: | Off, Chime, Home, Home Instant, Away, and Test |
| Sensor Types: | 11 including Automation, Emergency, Panic, Fire, Perimeter, Exit/Entry, Interior Chime Only, Arm/Disarm A, Arm/Disarm B, and Environmental |
| Auxiliary Outputs: | Automation, External Console Speaker, and External Alarm Siren |
| Memory: | EEPROM retains system programming during total power failure |
| Operating Temperature: | 32¢X to 120¢X F (0¢X to 49¢X C) |
|
COMMUNICATOR |
|
| Dialing: | DTMF or pulse dialing; pulse speed (10 PPS, 60% break, 40% make) |
| Ringer Equivalence: | 0.4 B |
| Reporting Formats: | 4 x 2, 40 PPS, or Ademco Contact ID |
|
Telephone Numbers: |
Primary, secondary, and supervisory |
| Reports: | Full zone reports, console reports, general system reports, forced arming, and duress PAC |
|
PHYSICAL CONSOLE |
|
| Dimensions: | 10.5 in L x 7.75 in W x 2.87 in H (267 x 197 x 73 mm) |
| Weight: | 3 lbs. (1.36 kg) |
¡@
¡@